High-speed 2D/3D Laser Profiler

LJ-V7000 series

Catalogues View Catalogue

Sensor head (Light intensity output type) LJ-V7200B

LJ-V7200B - Sensor head (Light intensity output type)

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD Data

360°view (3D PDF)

Software

  • CE Marking

Specifications

Model

LJ-V7200B

Mounting conditions

Diffuse reflection

Reference distance

200 mm

Measurement range

Z-axis (height)

±48 mm
(F.S.=96 mm)

X-axis (width)

NEAR side

51 mm

Reference distance

62 mm

Far side

73 mm

Light source

Type

Blue semiconductor laser

Wavelength

405 nm (visible beam)

Laser class

Class 2 Laser Product
(IEC60825-1, FDA(CDRH) Part 1040.10*1)

Output

4.8 mW

Spot size (reference distance)

Approx. 90 mm × 85 µm

Repeatability

Z-axis (height)

1 µm*2*3

X-axis (width)

20 µm*2*4

Linearity

Z-axis (height)

±0.1% of F.S.*5

Profile data interval

X-axis (width)

100 µm

Sampling cycle (trigger interval)

Top speed: 125 µs*6

Temperature characteristics

0.01% of F.S./°C

Environmental resistance

Enclosure rating

IP67 (IEC60529)*7

Ambient light

Incandescent lamp: 10,000 lux max.*8

Ambient temperature

0 to +45 °C*9

Relative humidity

85% RH or less (no condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 3 hours in each of the X, Y, and Z directions

Shock resistance

15 G/6 ms

Material

Aluminium

Weight

Approx. 550 g

*1 The laser classification for FDA(CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*2 This value is from a case in which measurement has been performed with a reference distance with 4,096 times of averaging.
*3 The measurement targets are KEYENCE standard targets. This value is from a case in which the average height of the default setting area has been measured in height mode. All other settings are default.
*4 The measurement target is a pin gauge. This value is from a case in which the position of the intersection between the rounded surface of the pin gauge and the edge level has been measured in position mode. All other settings are default.
*5 The measurement targets are KEYENCE standard targets. The profile data is from a case in which measurement has been performed with 64 times of smoothing and 8 times of averaging. All other settings are default.
*6 Sampling frequency depends on the setting of measurement range, binning and parallel imaging.
*7 This value is from a case in which the sensor head cable (CB-B*) or extension cable (CB-B*E) has been connected.
*8 This is the illuminance for the light-receiving surface of the sensor head during white paper measurement when light has been shined onto the white paper.
*9 The sensor head must be mounted on a metal plate for use.