Separate Amplifier Model, Sensor Head, 250mm range, 2m Cable LR-XH250

LR-XH250 - Separate Amplifier Model, Sensor Head, 250mm range, 2m Cable

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD Data

360°view (3D PDF)

Software

  • CE Marking
  • CSA

Specifications

Model

LR-XH250

Type

Cable Length: 2 m

Detecting Distance

30 to 250 mm

Standard Detectable Deviation

30 to 180 mm: 9 mm, 180 to 250 mm: 18 mm

Display Resolution

1 to 2 mm

Spot Size

Approx. 0.8 mm × Approx. 1.2 mm
(at a detecting distance of 250 mm)

Light Source

Type

Green laser (505 nm)

Laser Class

Class 1 laser product (IEC60825-1, FDA (CDRH), Part1040.10*1)

Environmental resistance

Enclosure rating

IP65/IP67(IEC60529)

Ambient light

Incandescent lamp: 8,000 lx or less,
Sunlight: 8,000 lx or less

Ambient temperature

-10°C to +50°C (no freezing)

Relative humidity

35 to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axes

Shock resistance

1,000 m/s2 (100G); 6 times each for X, Y, and Z axes

Material

Case: SUS316L; Lens Cover: PSU; Packing: FKM (lens cover), EVM (cable)

Accessories

Laser warning label

Weight

approx. 75 g

*1 Classification performed based on IEC60825-1 standards in accordance with FDA (CDRH) Laser Notice No. 56.

Data Sheet (PDF) Other Models