High-Accuracy Digital Contact Sensor

GT2 series

Catalogues View Catalogue

Stylus type General-purpose Sensor head GT2-P12

GT2-P12 - Stylus type General-purpose Sensor head

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD Data

360°view (3D PDF)

Software

  • CE Marking

Specifications

Model

GT2-P12*1

Detection system

Scale Shot System II, absolute (no tracking errors) type

Measuring range

12 mm

Resolution

0.5 μm

Indicated accuracy

2 µm (p-p)*2

Measuring force

Downward mounting

1.0 N*3

Side mounting

0.95 N*3

Upward mounting

0.9 N*3

Sampling cycle

4 ms

Mechanical response

10 Hz*2

Operation indicator light

2-colour LED (red, green)

Environmental resistance

Enclosure rating

IP67G (JIS)*4, IP67 (IEC), NEMA Type 13*4

Ambient temperature

-10 to +55 °C (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2 (IEC60068-2-27)

Materials

Main body

Main body case: SUS 303, Status indicator: PET, Sensor head-relay connector cable: PUR, Relay connector: PBT, Spindle of GT2-PA12K/PA12: SUS430 (Fluorine coating)

Dust boot

NBR

Contact

SUS304, SUS440C*5

Sensor head cable

Optional (connect to relay connector)

Weight

Approx. 35 g (not including cable)*6

*1 Note: You may not be able to connect the sensor head to the amplifier unit depending on when the amplifier unit was purchased.For details, contact your local sales office.
*2 Value when the ambient temperature is 20 °C.
*3 Representative value at the centre of the measuring range. Please note that the measuring force varies by the installation state of the dust boot. This is a representative value when using the GT2-PA12K/PA12 with a pressure of 0.25 MPa. The measuring force varies depending on the air pressure used. For details, see table 1.
No dust boots are used with the GT2-PA12K/PA12.
*4 When an M8 oil-resistant cable (GT2-CHP2M/CHP5M/CHP10M) is used for the sensor head cable.
*5 Contacts are available as options sold separately.
*6 Including the relay connector.

Data Sheet (PDF) Other Models