3D Scanner CMM Stage VL-750

VL-750 - 3D Scanner CMM Stage

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

  • CE Marking
  • CSA

Specifications

Model

VL-750

Type

Stage

Controller

VL-700

Measurement unit

VL-770

Optical transmitter system

High-brightness dual projector module

Optical receiver system

Low/high magnification offset dual optical module with wide dynamic range

Light sources

Measurement light source

Blue LED

Colour texture light source

LEDs in 3 colours (red, green, blue)

Captured data format

Full-colour textured 3D mesh data

Repeatability (σ)

2 μm *1

Measurement accuracy

±10 μm *2

Measurement resolution

9 million points

Measurement modes

Low magnification

High speed, Normal, Fine (wide field)

High magnification

Normal, Fine (High resolution)

Measurement range

Low magnification

ø300 × H 200 mm (wide field)

High magnification

ø70 × H 50 mm (High resolution)

Extended measurement

Automatic rotation combined measurements

Automatic XY combined measurements

Automatic XY combined measurement range

Low magnification (2 × 2 composition)

ø500 × H 200 mm

Low magnification (3 × 1 composition)

W 580 × D 300 × H 200 mm*3

High magnification (2 × 2 composition)

ø110 × H 50 mm

High magnification (3 × 1 composition)

W 150 × D 70 × H 50 mm*3

Stage

Stage configuration

Motorised XYθ stage mechanism

Stage top panel size

ø500 mm

Stage rotation

360° (infinite rotation)

Stage movement range

ø200 mm

Tilt mechanism

Up to 45°

Load capacity

50 kg

Control PC

Dedicated PC specified by KEYENCE

Power supply

Power voltage

100 to 240 VAC ±10%, 50/60 Hz

Power consumption

Controller/Measurement unit: 320 VA
Stage: 80 VA

Environmental resistance

Ambient temperature range

+15 to +30°C

Ambient humidity range

20 to 80% RH (no condensation)

Weight

Controller: 3.7 kg
Stage: 26 kg
Light-blocking cover: 5.5 kg
Measurement unit: 19.6 kg

*1 Value when measurement is performed using the default measurement mode specified by KEYENCE and using the default standard gauge specified by KEYENCE and at an operating ambient temperature of 23°C ±1°C
*2 In reference to ISO 10360-8; Value when measurement is performed using the default measurement mode specified by KEYENCE and using the default standard gauge specified by KEYENCE and at an operating ambient temperature of 23°C ±1°C
*3 Largest width for long and circular shape range

Data Sheet (PDF) Other Models