Clamp-On Flow Sensor
FD-EC series
Specs Clamp-On Flow Sensor FD-EC series
Amplifier Units
Model |
FD-ECA1 |
FD-ECA1C |
FD-ECA0 |
|||
Image |
|
|
|
|||
Type |
Cable Type |
M12 connector type*5 |
Zero Line Type*6 |
|||
No. of control outputs |
2 |
─*7 |
||||
No. of analogue outputs |
1 |
─ |
||||
No. of external inputs |
─*7 |
|||||
Power supply cable |
2-m strand wire, 6-core |
100-mm pigtail, M12 terminal, 6 of 8 pins used |
No cable |
|||
Response time (90% response) |
50 ms/100 ms/250 ms/1 s/5 s (selectable, default 250 ms)*1 |
|||||
Input/output |
Control output 1, 2 |
Instantaneous flow/integrated flow/alert output/pulse output |
─ |
|||
Analogue output |
Instantaneous flow |
|||||
External input |
Zero flow adjustment/zero flow origin adjustment/accumulated flow reset |
|||||
Network compatibility |
IO-Link*2 |
NU Series |
||||
No. of expansion units |
─ |
8 units for one NU parent unit, 4 units for one |
||||
Protection circuit |
Protection against reverse power connection, output overcurrent, output surges, reverse output connection, head cable miswiring |
Protection against head cable miswiring |
||||
Power supply |
Power voltage |
24 VDC+20%/−10% (including ripple), Class2/LPS |
24 VDC±10% (including ripple), Class2/LPS |
|||
Power consumption |
1680 mW*3 (excluding load current) |
1290 mW (excluding load current) |
||||
Environmental resistance |
Ambient temperature |
-10 to +55°C (no freezing)*4 |
||||
Relative humidity |
35–85% RH (no condensation) |
|||||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions |
|||||
Shock resistance |
100 m/s2, 16 ms pulses, 1000 times each for X, Y, and Z directions |
|||||
Material |
Main unit: Polycarbonate, FG terminals: copper/iron |
|||||
Weight |
Approx. 90 g |
Approx. 42 g |
Approx. 26 g |
|||
*1 Analogue output response time is 5 ms additional and 63% response. |
Sensor head
Model |
FD-ECH6 |
FD-ECH7 |
FD-ECH8 |
FD-ECH9 |
FD-ECH10 |
FD-ECH12 |
FD-ECH13 |
|||
Image |
|
|
|
|
|
|
|
|||
Supported pipe diameter |
Pipe outer diameter |
ø6 |
1/4” (approx. 6.35 mm) |
ø8 |
3/8” (approx. 9.53 mm) |
ø10 |
ø12 |
1/2” (approx. 12.7 mm) |
||
Installable range |
6.0 ±0.15 mm |
6.35 ±0.15 mm |
8.0 ±0.15 mm |
9.53 ±0.15 mm |
10.0 ±0.15 mm |
12.0 ±0.15 mm |
12.7 ±0.15 mm |
|||
Pipe materials |
Polyurethane, nylon, PFA*1, others*2 |
|||||||||
Supported fluids |
Air, nitrogen, argon, other gases*3 |
|||||||||
Supported fluid temperatures |
−10 to +60°C |
|||||||||
Operating pressure range |
0 to 0.75 MPa (upper limit depends on pipe specifications) |
|||||||||
Flow detection principle |
Transmission time difference method |
|||||||||
Rated flow |
(volumetric flow) |
40 L/min *Initial display |
70 L/min *Initial display |
100 L/min *Initial display |
120 L/min *Initial display |
180 L/min *Initial display |
200 L/min *Initial display |
|||
(at 20°C, atmospheric pressure) |
Gas at 20°C, 0.2 MPa |
120 L/min |
210 L/min |
300 L/min |
360 L/min |
540 L/min |
600 L/min |
|||
Gas at 20°C, 0.4 MPa |
200 L/min |
350 L/min |
500 L/min |
600 L/min |
900 L/min |
1000 L/min |
||||
Gas at 20°C, 0.6 MPa |
280 L/min |
490 L/min |
700 L/min |
840 L/min |
1260 L/min |
1400 L/min |
||||
Repeatability |
2.5% of F.S. at 250-ms response time*4*5 |
|||||||||
Display resolution |
Instantaneous flow |
0.01/0.1/1 L/min |
0.1/1 L/min |
|||||||
Integrated flow |
0.01/0.1/1/10/100 L |
0.1/1/10/100/1000 L |
||||||||
Display method |
Output indicators |
|||||||||
Environmental resistance |
Enclosure rating |
IP65 (IEC60529) |
||||||||
Ambient temperature |
-10 to +60°C (no freezing) |
|||||||||
Relative humidity |
35–85% RH (no condensation) |
|||||||||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions |
|||||||||
Shock resistance |
100 m/s2, 16 ms pulses, 1000 times each for X, Y, and Z directions |
|||||||||
Material |
Sensor unit |
PBT/PAR/Iron |
||||||||
Sensor surface |
Special rubber |
|||||||||
Weight |
Approx. 102 g |
Approx. 105 g |
Approx. 114 g |
Approx. 115 g |
Approx. 116 g |
|||||
*1 PFA tubing should be used in environments of 40°C or less. |