Flow and Pressure Dual Sensor
FD-EP series
Amplifier Units Zero Line Type FD-EPA0
*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.
Specifications
Model | FD-EPA0 | |||
Type | Zero Line Type*1 | |||
No. of control outputs | ─*2 | |||
No. of analog outputs | ─ | |||
No. of external inputs | ─*2 | |||
Power supply cable | No cable | |||
Response time (90% response) | Flow | 50 ms/100 ms/250 ms/1 s/5 s (selectable, default 250 ms) *3 | ||
Pressure | 2.5 ms/10 ms/50 ms/100 ms/250 ms/1 s/5 s (selectable, default 2.5 ms) *3 | |||
Input/output | Control output 1, 2, 3 | Instantaneous flow/integrated flow/pressure/alert output/predictive maintenance output/seating (output 1 only)/pulse output NPN/PNP | ||
Analog output | Instantaneous flow/pressure 4–20 mA/0–20 mA (switchable), load resistance 260 Ω or less | |||
External inputs 1, 2 | Zero flow/flow origin adjustment/atmospheric pressure correction/pressure zero shift/accumulation reset/application learning/application reset | |||
Network compatibility | NU Series | |||
No. of expansion units | 8 units for one NU parent unit, 4 units for one | |||
Protection circuit | Protection against head cable miswiring | |||
Power supply | Power voltage | 24 VDC ±10% (including ripple), Class2/LPS | ||
Power consumption | 1400 mW (excluding load current)*4 | |||
Environmental resistance | Ambient temperature | -10 to +55°C (no freezing) *4 | ||
Relative humidity | 35–85% RH (no condensation) | |||
Vibration resistance | 10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions | |||
Shock resistance | 100 m/s2, 16 ms pulses, 1000 times each for X, Y, and Z directions | |||
Material | Main unit: Polycarbonate, FG terminals: copper/iron | |||
Weight | Approx. 26 g | |||
*1 The zero line type should be used by connecting to the FS-MC8N/P and NU Series. |