Specs Safety Laser Scanner SZ series

Model

SZ-01S

SZ-16V

Image

Type

Simple function type

Multi-zone sets (banks) type

Detection capability

Minimum detectable object size

Diameter 30 mm, 40 mm, 50 mm, 70 mm, 150 mm (depends on the setting)
Reflectance 1.8% min., Speed 1.6 m/s max.

Detectable angle

270° (-45° to 225°)

Response time (ON to OFF)

General scan cycle (Scan cycle A)

60 ms (2 scanning) to 480 ms (16 scanning)

Specific scan cycle (Scan cycle B)

66 ms (2 scanning) to 528 ms (16 scanning)

Response time (OFF to ON)

General scan cycle (Scan cycle A)

Response time of ON to OFF + 125 ms

Specific scan cycle (Scan cycle B)

Max. protection zone

Minimum detectable object size: 70 mm /150 mm

4.2 m (-5° to 185°), 2.8 m (-45° to -5°, 185° to 225°)

Minimum detectable object size: 50 mm

3.0 m (-5° to 185°), 2.0 m (-45° to -5°, 185° to 225°)

Minimum detectable object size: 40 mm

2.4 m (-5° to 185°), 1.6 m (-45° to -5°, 185° to 225°)

Minimum detectable object size: 30 mm

1.8 m (-5° to 185°), 1.2 m (-45° to -5°, 185° to 225°)

Max. warning zone (non safety related)

Minimum detectable object size: 70 mm /150 mm

10.0 m (-5° to 185°), 7.0 m (-45° to -5°, 185° to 225°)*1

Minimum detectable object size: 50 mm

7.5 m (-5° to 185°), 5.0 m (-45° to -5°, 185° to 225°)*1

Minimum detectable object size: 40 mm

6.0 m (-5° to 185°), 4.0 m (-45° to -5°, 185° to 225°)*1

Minimum detectable object size: 30 mm

4.5 m (-5° to 185°), 3.0 m (-45° to -5°, 185° to 225°)*1

Additional safety distance

100 mm*2

Light source

Type, wavelength

Infrared laser diode, 905 nm

Laser class

Class 1 IEC / EN 60825-1: 2007
Class 1 CFR 21 1040.10, 1040.11 (Laser Notice)
Class 1 JIS C6802: 2005

OSSD output

Output

PNP or NPN (Selectable according to the connector cable)
2 outputs

Max. load current

500 mA*3

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 5 m)

OFF-state voltage

Max. 2.0 V (with a cable length of 5 m)

Leakage current

Max. 1 mA*4

Max. capacitive load

2.2 µF (with a load resistance of 100 Ω)

Load wiring resistance

Max. 2.5 Ω*5

Input (safety-related)

Input resistance

4.4 kΩ (for Input 1)
2.2 kΩ (for Input 2)

4.4 kΩ (for Input 1 and 3 to 10)
2.2 kΩ (for Input 2)

Nonsafety-relatedoutput (AUX output)

Output

PNP/NPN totem pole output
2 outputs

PNP/NPN totem pole output
4 outputs

Max. load current

50 mA

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 5 m)

Cable length

30 m or less*6

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL 61496-1

EMI

EN55011 Class A, FCC Part15B Class A

Safety

IEC61496-1, EN61496-1, UL 61496-1 (Type 3 ESPE)
IEC61496-3, EN61496-3 (Type 3 AOPDDR)
IEC61508, EN61508, IEC62061, EN62061 (SIL2)
EN ISO13849-1:2015 (PL d, Category 3)
UL508, UL1998

Rating

Power voltage

When using a converter power supply: 24 VDC ±10 %, Ripple (P-P) 10 % or less
When using a battery: 24 VDC +20 % /-30 %

Power consumption

Max. 9.5 W (without load)
Max. 39 W (with load)

Max. 10.5 W (without load)
Max. 43 W (with load)

Environmental resistance

Enclosure rating

IP65 (IEC60529)*7

Ambient light

Incandescent lamp: 1,500 lux or less*8

Operating ambient temperature

-10 to +50 °C (No freezing)

Storage temperature

-25 to +60 °C (No freezing)

Operating relative humidity

35 to 85 % RH (No condensation)

Storage relative humidity

35 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum die casting, SPHC (Bottom)

Window

Polycarbonate

Weight

Approx. 1.6 kg

*1 20% or more reflectance is necessary for the minimum detectable object in the warning zone.
*2 If there is a high reflective background within 1.5 m from the boundary of the protection zone, 200 mm must be added as supplementary necessary distance to the protection zone in case of calculation of the minimum safety distance.
*3 For the load current calculation of the OSSD output and the AUX output, make sure it is 1.5 A or less when using converter power supply (or 1.0 A or less when the cable length is 25 m or more), and 1.0 A or less when using a battery (or 0.5 A or less when the cable length is 5 m or more).
*4 This also takes into account the situations when power is either off or disconnected.
*5 The wiring resistance between the OSSD output and the connected equipment (excluding the resistance of the cable) must be 2.5 Ω or less to ensure operation. However, it must be 1.0 Ω or less if the load current is 300 mA or more.
*6 It must be 10 m or less if the power is supplied by the battery.
*7 When the setting cover is open, or the connector cable is not connected, the IP65 certification cannot be met.
*8 The SZ should not be installed so as to have light interference within ±5° to the detection plane.

Back to top