Amplifier Separate Type Photoelectric Sensor
PS-N series
Specs Amplifier Separate Type Photoelectric Sensor PS-N series
Thrubeam type sensor head: General purpose
Model |
PS-55 |
PS-55C*3 |
PS-05 |
PS-58 |
PS-52 |
PS-52C*3 |
PS-56 |
|||
Image |
|
|
|
|
|
|
|
|||
Type |
Thrubeam, General purpose, Long-detecting distance |
Thrubeam, General purpose, Free-positioning |
Thrubeam, General purpose, Cylindrical |
Thrubeam, General purpose, Thin |
||||||
Detecting distance |
TURBO |
4,000 mm*1 |
- |
600 mm*1 |
- |
|||||
FINE |
2,000 mm |
300 mm |
||||||||
Light source |
Infrared LED |
|||||||||
Smallest detectable object |
TURBO |
2.0 mm dia. opaque*2 |
- |
0.3 mm dia. opaque*2 |
- |
|||||
FINE |
1.0 mm dia. opaque*2 |
0.5 mm dia. opaque*2 |
0.3 mm dia. opaque*2 |
|||||||
Environmental resistance |
Enclosure rating |
IP64 |
IP67 |
- |
||||||
Ambient light |
Incandescent lamp: 4,000 lux max., Sunlight: 12,000 lux max. |
|||||||||
Ambient temperature |
-10 to +60 °C (No freezing) |
|||||||||
Relative humidity |
35 to 85 % RH (No condensation) |
|||||||||
Weight |
Approx. 30 g (Including cable) |
|||||||||
*1 For models with no specification, use FINE mode only. |
Thrubeam type sensor head: Environment-proof
Model |
PS-201 |
PS-201C*3 |
PS-202 |
|||
Image |
|
|
|
|||
Type |
Thrubeam, PFA-sheathed, Long-detecting distance |
Thrubeam, PFA-sheathed, Aperture-incorporated |
||||
Detecting distance |
TURBO |
4,000 mm*1 |
1,000 mm*1 |
|||
FINE |
2,000 mm |
500 mm |
||||
Light source |
Infrared LED |
|||||
Smallest detectable object |
TURBO |
1.2 mm dia. opaque*2 |
0.5 mm dia. opaque*2 |
|||
FINE |
0.8 mm dia. opaque*2 |
|||||
Environmental resistance |
Enclosure rating |
IP67 |
||||
Ambient light |
Incandescent lamp: 4,000 lux max., Sunlight: 12,000 lux max. |
|||||
Ambient temperature |
-10 to +60 °C (No freezing) |
|||||
Relative humidity |
35 to 85 % RH (No condensation) |
|||||
Weight |
Approx. 40 g (Including cable) |
|||||
*1 For models with no specification, use FINE mode only. |
Diffuse-reflective sensor head
Model |
PS-45 |
PS-46 |
PS-48 |
PS-205 |
PS-206 |
|||
Image |
|
|
|
|
|
|||
Type |
Diffuse-reflective, General purpose, Long-detecting distance |
Diffuse-reflective, General purpose, Thin |
Diffuse-reflective, General purpose, Cylindrical |
Diffuse-reflective, PFA-sheathed, Long-detecting distance |
Diffuse-reflective, PFA-sheathed, Narrow-beam |
|||
Detecting distance |
TURBO |
400 mm*1 |
- |
400 mm*1 |
- |
|||
FINE |
200 mm |
100 mm |
25 mm |
200 mm |
70 mm |
|||
Light source |
Infrared LED |
Red LED |
||||||
Detectable object |
Transparent and opaque |
|||||||
Spot diameter |
- |
6 mm dia. |
||||||
Hysterese |
15% max. |
10% max. |
20% max. |
15% max. |
||||
Environmental resistance |
Enclosure rating |
IP64 |
- |
IP67 |
||||
Ambient light |
Incandescent lamp: 4,000 lux max., Sunlight: 12,000 lux max. |
|||||||
Ambient temperature |
-10 to +60 °C (No freezing) |
|||||||
Relative humidity |
35 to 85 % RH (No condensation) |
|||||||
Weight |
Approx. 30 g (Including cable) |
Approx. 40 g (Including cable) |
Approx. 60 g (Including cable) |
|||||
*1 For models with no specification, use FINE mode only. |
Definite-reflective sensor head
Model |
PS-47 |
PS-47C*2 |
PS-49 |
PS-49C*2 |
|||
Image |
|
|
|
|
|||
Type |
Definite-reflective, General purpose, Small spot |
Definite-reflective, General purpose, Long-detecting distance |
|||||
Detecting distance |
TURBO |
- |
|||||
FINE |
10 mm (at centre) |
32 mm to 53 mm |
|||||
Light source |
Red LED |
||||||
Detectable object |
Transparent and opaque |
||||||
Smallest detectable object |
0.03 mm dia. copper wire*1 |
0.1 mm dia. copper wire*1 |
|||||
Spot diameter |
0.8 mm dia. |
1.5 mm dia. |
|||||
Hysterese |
3% max. |
6% max. |
|||||
Environmental resistance |
Ambient light |
Incandescent lamp: 4,000 lux max., Sunlight: 5,000 lux max. |
|||||
Ambient temperature |
-10 to +60 °C (No freezing) |
-10 to +50 °C (No freezing) |
|||||
Relative humidity |
35 to 85 % RH (No condensation) |
||||||
Weight |
Approx. 30 g (Including cable) |
||||||
*1 With thrubeam sensors, the smallest detectable object indicates the size of a detectable object from the maximum detecting distance. |
Amplifier: NPN
Model |
PS-N11N |
PS-N12N |
PS-N11CN |
PS-N12CN |
|||
Image |
|
|
|
|
|||
Type |
Cable |
M8 connector |
|||||
Output |
NPN |
||||||
Main unit/Expansion unit |
Main unit |
Expansion unit |
Main unit |
Expansion unit |
|||
I/O |
Control outputs |
1 output |
|||||
External input |
1 input |
None |
1 input |
||||
Output selection |
LIGHT-ON/DARK-ON (switch-selectable) |
||||||
Timer function |
Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, Timer duration selectable: 1 ms to 9999 ms, Maximum error against the setting value: ±10% max. |
||||||
Control output |
NPN open collector 30 V, (without expansion) 100 mA max., (with expansion) 20 mA max, |
||||||
Number of interference prevention units |
4 for TURBO/SUPER/ULTRA/MEGA (When set to DOUBLE, the number of interference-prevention units will be doubled) |
||||||
Response time |
500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) |
||||||
External input |
Input time 2 ms (ON)/20 ms (OFF) or more*1 |
||||||
Case size |
H 32.6 mm × W 9.8 mm × L 78.7 mm |
||||||
Unit expansion |
Up to 16 units (Up to 17 units including 1 main unit can be connected in total.) |
||||||
Protection circuit |
Reverse polarity protection, Over-current protection, Surge absorber |
||||||
Rating |
Power voltage |
24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS |
|||||
Power consumption |
Normal: 810 mW or less (at 30V. 28 mA max. at 24 V, 34 mA max. at 12 V) |
||||||
Environmental resistance |
Ambient temperature |
-20 to +55 °C (No freezing)*2 |
|||||
Relative humidity |
35 to 85 % RH (No condensation) |
||||||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions |
||||||
Shock resistance |
500 m/s2, 3 times in each of the X, Y, and Z directions |
||||||
Material |
Case |
Main unit and cover material: Polycarbonate |
|||||
Cable |
PVC |
||||||
Weight |
Approx. 75 g |
Approx. 65 g |
Approx. 20 g |
||||
*1 Input time is 25 ms (ON)/25 ms (OFF) when the external calibration time is selected. |
Amplifier: PNP
Model |
PS-N11P |
PS-N12P |
PS-N11CP |
PS-N12CP |
|||
Image |
|
|
|
|
|||
Type |
Cable |
M8 connector |
|||||
Output |
PNP |
||||||
Main unit/Expansion unit |
Main unit |
Expansion unit |
Main unit |
Expansion unit |
|||
I/O |
Control outputs |
1 output |
|||||
External input |
1 input |
None |
1 input |
||||
Output selection |
LIGHT-ON/DARK-ON (switch-selectable) |
||||||
Timer function |
Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, Timer duration selectable: 1 ms to 9999 ms, Maximum error against the setting value: ±10% max. |
||||||
Control output |
PNP open collector 30 V, (without expansion) 100 mA max., (with expansion) 20 mA max, |
||||||
Number of interference prevention units |
4 for TURBO/SUPER/ULTRA/MEGA (When set to DOUBLE, the number of interference-prevention units will be doubled) |
||||||
Response time |
500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) |
||||||
External input |
Input time 2 ms (ON)/20 ms (OFF) or more*1 |
||||||
Case size |
H 32.6 mm × W 9.8 mm × L 78.7 mm |
||||||
Unit expansion |
Up to 16 units (Up to 17 units including 1 main unit can be connected in total.) |
||||||
Protection circuit |
Reverse polarity protection, Over-current protection, Surge absorber |
||||||
Rating |
Power voltage |
24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS |
|||||
Power consumption |
Normal: 860 mW or less (at 30 V. 30 mA max. at 24 V, 35 mA max. at 12 V) |
||||||
Environmental resistance |
Ambient temperature |
-20 to +55 °C (No freezing)*2 |
|||||
Relative humidity |
35 to 85 % RH (No condensation) |
||||||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions |
||||||
Shock resistance |
500 m/s2, 3 times in each of the X, Y, and Z directions |
||||||
Material |
Case |
Main unit and cover material: Polycarbonate |
|||||
Cable |
PVC |
||||||
Weight |
Approx. 75 g |
Approx. 65 g |
Approx. 20 g |
||||
*1 Input time is 25 ms (ON)/25 ms (OFF) when the external calibration time is selected. |