CMOS Multi-Function Analogue Laser Sensor

IL series

Catalogues View Catalogue

Specs CMOS Multi-Function Analogue Laser Sensor IL series

Model

IL-S025

IL-S065

Image

Reference distance

25 mm

65 mm

Measurement range

20 to 30 mm

55 to 75 mm

Light source

Type

Red semiconductor laser, wavelength: 655 nm (visible light)

Laser class

Class 2 (FDA (CDRH) Part1040.10)*1, Class 2 (IEC 60825-1)

Output

560 µW

Spot diameter (at standard distance)

Approx. 25 x 1,200 µm

Approx. 55 x 1,700 µm

Linearity

±0.075% of F.S. (20 to 25 mm)*2*3
±0.1% of F.S. (20 to 30 mm)*2*3

±0.05% of F.S. (55 to 65 mm)*2*3
±0.075% of F.S. (55 to 75 mm)*2*3

Repeatability

1 µm*4

2 µm*4

Sampling rate

0.33/1/2/5 ms (4 levels available)

Operation status indicators

Laser emission warning indicator: Green LED, Analogue range indicator: Orange LED, Reference distance indicator: Red/Green LED

Temperature characteristics

0.03% of F.S./°C*3

0.02% of F.S./°C*3

Environmental resistance

Enclosure rating

IP67

Pollution degree

3

Ambient light

Incandescent lamp: 10,000 lux*5

Ambient temperature

-10 to +50 °C (No condensation or freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Material

Housing material: PBT, Metal parts: SUS304, Packing: NBR, Lens cover: Glass, Cable: PVC

Weight

Approx. 60 g

Approx. 75 g

*1 The laser classification for FDA (CDRH) is implemented based on IEC 60825-1 in accordance with the requirements of Laser Notice.
*2 Value when measuring the KEYENCE standard target (white diffuse object).
*3 F.S. of each model is as follows. IL-S025: ±5 mm IL-S065: ±10 mm
*4 Value when measuring the KEYENCE standard target (white diffuse object) at the reference distance, sampling rate: 1 ms, and average number of times: 128.
*5 Value when the sampling rate is set to 2 ms or 5 ms.

Back to top

Model

IL-030

IL-065

IL-100

IL-300

IL-600

IL-2000*6

Image

Reference distance

30 mm

65 mm

100 mm

300 mm

600 mm

2000 mm

Measurement range

20 to 45 mm

55 to 105 mm

75 to 130 mm

160 to 450 mm

200 to 1000 mm

1000 to 3500 mm

Light source

Type

Red semiconductor laser, wavelength: 655 nm (visible light)

Red semiconductor laser, wavelength: 655 nm (visible light)

Laser class

Class 1 (FDA (CDRH) Part1040.10)*1
Class 1 (IEC 60825-1)

Class 2 (FDA (CDRH) Part1040.10)*1
Class 2 (IEC 60825-1)

Class 2 laser product (FDA (CDRH) Part 1040.10,*7 IEC 60825-1)

Output

220 µW

560 µW

Spot diameter (at standard distance)

Approx. 200 x 750 µm

Approx. 550 x 1,750 µm

Approx. 400 x 1,350 µm

Approx. ø0.5 mm

Approx. ø1.6 mm

Approx. 1,400 x 7,000 µm

Linearity

±0.1% of F.S. (25 mm to 35 mm)*2*3

±0.1% of F.S. (55 mm to 75 mm)*2*3

±0.15% of F.S. (80 mm to 120 mm)*2*3

±0.25% of F.S. (160 mm to 440 mm)*2*3

±0.25% of F.S. (200 to 600 mm)*2*3
±0.5% of F.S. (200 to 1000 mm)*2*3

±0.16% of F.S.
(When used under
1000 to 3500 mm)*8

Repeatability

1 µm*4

2 µm*4

4 µm*4

30 µm*4

50 µm*4

100 µm*9

Sampling rate

0.33/1/2/5 ms (4 levels available)

0.33/1/2/5 ms (Variable to 4 levels)

Operation status indicators

Laser emission warning indicator: Green LED, Analogue range indicator: Orange LED, Reference distance indicator: Red/Green LED

Laser emission warning indicator: green LED, Analog range indicator: orange LED, Reference distance indicator: red/green LED

Temperature characteristics

0.05% of F.S./°C*3

0.06% of F.S./°C*3

0.08% of F.S./°C*3

0.016% of F.S./°C*10

Environmental resistance

Enclosure rating

IP67

Pollution degree

3

Ambient light

Incandescent lamp: 5,000 lux*5

Incandescent lamp: 7,500 lux*5

Incandescent lamp: 5,000 lux*5

Incandescent lamp: 10,000 lux*5

Ambient temperature

-10 to +50 °C (No condensation or freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Material

Housing material: PBT, Metal parts: SUS304, Packing: NBR, Lens cover: Glass, Cable: PVC

Housing material: PBT, Metal: SUS304, Packing: NBR, Lens cover: Glass, Cable: PVC

Weight

Approx. 60 g

Approx. 75 g

Approx. 135 g

Approx. 350 g

*1 The laser classification for FDA (CDRH) is implemented based on IEC 60825-1 in accordance with the requirements of Laser Notice.
*2 Value when measuring the KEYENCE standard target (white diffuse object).
*3 F.S. of each model is as follows. IL-030: ±5 mm IL-065: ±10 mm IL-100: ±20 mm IL-300: ±140 mm IL-600: ±400 mm
*4 Value when measuring the KEYENCE standard target (white diffuse object) at the reference distance, sampling rate: 1 ms, and average number of times: 128. For the IL-300/IL-600, the sampling rate is 2 ms.
*5 Value when the sampling rate is set to 2 ms or 5 ms.
*6 Amplifiers purchased before August 8th, 2012 cannot be used.
*7 The laser classification is implemented based on IEC 60825-1 in accordance with the requirements of FDA (CDRH) Laser Notice.
*8 Value when measuring the KEYENCE standard target (white diffuse object). F.S. for each model is as follows: IL-030: ±5 mm IL-065: ±10 mm IL-100: ±20 mm IL-300: ±140 mm IL-600: ±400 mm
*9 Value when measuring the KEYENCE standard target (white diffuse object) at the reference distance, sampling rate: 1 ms, and average number of times: 16. For the IL-300/IL-600, the sampling rate is 2 ms.
*10 F.S. for each model is as follows: IL-030: ±5 mm IL-065: ±10 mm IL-100: ±20 mm IL-300: ±140 mm IL-600: ±400 mm

Back to top

Amplifier

Model

IL-1000

IL-1500

IL-1050

IL-1550

Image

Type

DIN-rail mount

Panel mount

DIN-rail mount

Panel mount

Main unit/Expansion unit

Main unit

Expansion unit

Head compatibility

Compatible

Display

Minimum
displayable unit

IL-S025/IL-030: 1 µm, IL-S065/IL-065/IL-100: 2 µm, IL-300: 10 µm, IL-600: 50 µm

Display range

IL-S025/IL-030/IL-S065/IL-065/IL-100: ±99.999 mm to ±99 mm (4 levels selectable),
IL-300/IL-600: ±999.99 mm to ±999 mm (3 levels selectable)

Display rate

Approx. 10 times/sec.

Analogue voltage output

±5 V, 1 to 5 V, 0 to 5 V Output impedance 100 Ω*1

None

Analogue current output

4 to 20 mA Maximum load resistance of 350 Ω*1

Control input

Bank switch input

Non-voltage input*2

Zero-shift input

Stop emission input

Timing input

Reset input

Control output

Judgment output

Open collector output (NPN, PNP changeover possible/N.O., N.C. changeover possible)*3

Alarm output

Open collector output (NPN, PNP changeover possible/N.C.)*3

Current

Power voltage

10 to 30 VDC ripple (P-P) 10% included, Class 2*4

Supplied by main unit*4

Power consumption

2300 mW or less (at 30 V: 77 mA or less)

2500 mW or less (at 30 V: 84 mA or less)

2000 mW or less (at 30 V: 67 mA or less)

2200 mW or less (at 30 V: 74 mA or less)

Environmental resistance

Pollution degree

2

Ambient temperature

-10 to +50 °C (No condensation or freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Material

Case / Front sheet: Polycarbonate; Key tops: Polyacetel; Cable: PVC

Weight

Approx. 150 g (including attachments)

Approx. 170 g (including attachments)

Approx. 140 g (including attachments)

Approx. 160 g (including attachments)

*1 Select and use one of ±5 V, 1 to 5 V, 0 to 5 V or 4 to 20 mA.
*2 Assign an input of your choice to the 4 external input lines before using.
*3 The NPN open collector rated output is: 50 mA max./ch (20 mA when adding an expansion unit) less than 30 V, residual voltage less than 1 V (less than 1.5 V when adding over 6 units including the main unit)
The PNP open collector rated output is: 50 mA max./ch (20 mA/ch when adding expansion units), less than power voltage, and less than 2 V residual voltage (less than 2.5 V when adding over 6 units including the main unit)
*4 If there are over 6 additional expansion units, please use a power voltage of 20 to 30 V.

Back to top