Two-wire self contained amplifier proximity sensors
EV series
Specs Two-wire self contained amplifier proximity sensors EV series
Model |
EV-108M |
EV-112M |
EV-118M |
|||
Image |
|
|
|
|||
Type |
DC , Shielded |
|||||
Shape |
M8 |
M12 |
M18 |
|||
Detecting distance |
1.5 mm ±10% |
2.5 mm ±10% |
5 mm ±10% |
|||
Detectable object |
Ferrous metals (see Characteristics for nonferrous metals) |
|||||
Standard target |
10 x 10 mm |
12 x 12 mm |
18 x 18 mm |
|||
Hysteresis |
10% max. of detecting distance |
|||||
Response frequency |
800 Hz |
600 Hz |
350 Hz |
|||
Operation mode |
N.O. |
|||||
Temperature characteristics |
±10% max. of detecting distance at +23°C, within -25 to +70°C |
|||||
Control output |
5 to 80 mA |
5 to 200 mA |
||||
Protection circuit |
Reversed polarity,surge voltage |
Reversed polarity, short-circuit, surge voltage |
||||
Cable length |
2 m |
|||||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 20 % or less |
||||
Current consumption (leakage |
Current consumption (leakage current): 1.0 mA max., Residual voltage: 3.6 V max. (with 2-m cable) |
|||||
Residual voltage |
Residual voltage: 3.6 V max. (with 2-m cable) |
|||||
Environmental resistance |
Enclosure rating |
IP67 |
||||
Ambient temperature |
-25 to +80 °C (No freezing) |
|||||
Relative humidity |
35 to 95 % RH (No condensation) |
|||||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions |
|||||
Shock resistance |
500 m/s2, 3 times in each of the X, Y, and Z directions |
1,000 m/s2, 3 times in each of the X, Y, and Z directions |
||||
Case material |
Stainless steel (SUS304) |
Nickel-plated brass |
||||
Accessories |
Nut × 2, toothed washer × 1, instruction manual |
|||||
Weight |
Approx. 42 g |
Approx. 110 g |
Approx. 150 g |
Model |
EV-112U |
EV-118U |
EV-130U |
|||
Image |
|
|
|
|||
Type |
DC , Non-shielded |
|||||
Shape |
M12 |
M18 |
M30 |
|||
Detecting distance |
8 mm ±10% |
15 mm ±10% |
27 mm ±10% |
|||
Detectable object |
Ferrous metals (see Characteristics for nonferrous metals) |
|||||
Standard target |
30 x 30 mm |
50 x 50 mm |
70 x 70 mm |
|||
Hysteresis |
20% max. of detecting distance, within -10 to +70°C (14 to 158°F) |
|||||
Response frequency |
600 Hz |
350 Hz |
250 Hz |
|||
Operation mode |
N.O. |
|||||
Temperature characteristics |
±10% max. of detecting distance, |
-5 to +20%, |
||||
Control output |
5 to 200 mA |
|||||
Protection circuit |
Reversed polarity, short-circuit, surge voltage |
|||||
Cable length |
2 m |
|||||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 20 % or less |
||||
Current consumption (leakage |
Current consumption (leakage current): 1.0 mA max., Residual voltage: 3.6 V max. (with 2-m cable) |
|||||
Residual voltage |
Residual voltage: 3.6 V max. (with 2-m cable) |
|||||
Environmental resistance |
Enclosure rating |
IP67 |
||||
Ambient temperature |
-25 to +80 °C (No freezing) |
|||||
Relative humidity |
35 to 95 % RH (No condensation) |
|||||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions |
|||||
Shock resistance |
500 m/s2, 3 times in each of the X, Y, and Z directions |
1,000 m/s2, 3 times in each of the X, Y, and Z directions |
||||
Case material |
Nickel-plated brass |
|||||
Accessories |
Nut × 2, toothed washer × 1, instruction manual |
|||||
Weight |
Approx. 110 g |
Approx. 140 g |
Approx. 260 g |