Standard Static Elimination Blower

SJ-F100 series

This model has been discontinued.
Compliance with the certification standard is ensured as of the time of shipment from our company.

Recommended Replaceable Products: Multi-Sensor Ionizer - SJ-F700 series

Blower Type Main Unit SJ-F010

SJ-F010 - Blower Type Main Unit

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD Data

360°view (3D PDF)

  • CE Marking

Specifications

Model

SJ-F010

Type

Static elimination blower

Controller

SJ-F100W

Voltage application method

Variable DC

Applied voltage

Max. ±7000 V

Ion balance control method

I.C.C. method

Static elimination time

Approx 1sec*1

Ion balance

±5 V*1

Maximum wind speed

1.5m/s*1

Maximum air volume

1m3/min

Ozone density

0.005ppm or less

Control input

Static eliminationstop input

NPN open collector or non-voltage contact signal

Controloutput

Alarm output

NPN: 100 mA max. (40 V Max.)

Ion level alert output

Condition alert output

Rating

Power voltage

24 VDC ±10 %

Current consumption

450 mA or less

Environmental resistance

Ambient temperature

0 to +50 °C

Relative humidity

35 to 65 % RH (No condensation)

Weight

Approx. 400 g

*1 When measured at 200 mm from the front of the static elimination blower

Data Sheet (PDF) Other Models