Specs High-Accuracy High-Speed Sensing Ionizer SJ-Q series

Model

SJ-Q036

SJ-Q060

SJ-Q084

SJ-Q108

SJ-Q132

Image

Data Sheet (PDF)

Download

Download

Download

Download

Download

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/
applied voltage

Pulse AC method/±8000 Vmax

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±3 V *1

Clean rating

ISO14644-1 Class 3 *2

Operating distance

10 mm or more

Control input

Static elimination stop input

NPN open collector or non-voltage contact signal

Control output

Ion level alarm

NPN open collector
Maximum 100 mA (40 VDC or less)

Condition alarm

Alarm output

Communication functions

Remote control

Average power consumption

Normal operation: 8.4 W,
LPC mode: 4.1 W
*3

Major features

Condition alarm, ion level alarm, alarm output

Air connection port

Rc1/8

Air supply pressure

0.1 to 0.5 MPa (recommended air pressure: 0.2 MPa)*4

Effective length

440 mm *5

680 mm *5

920 mm *5

1160 mm *5

1400 mm *5

Total length

350 mm

560 mm

800 mm

1040 mm

1280 mm

No. of electrodes

5

9

13

17

21

Rating

Power voltage

24 to 36 VDC±10%

Current consumption

Normal operation: 700 mA or less,
LPC mode: 170 mA (typical)
*3

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C

Relative humidity

85% RH or less (no condensation)

Material

Electrode probe

Tungsten

Body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

690 g

890 g

1120 g

1340 g

1580 g

*1 Measured under the following conditions.
Installation distance: 300 mm, Air supply pressure: 0.2 MPa, Frequency: Highest device driving frequency, Operating ambient temperature: 0 to +40°C, Operating ambient humidity: 35 to 65% RH, Measurement position: Bar centre
*2 Contact us for detailed conditions.
*3 24 VDC
*4 If you wish to use the air purge function with intermittent air supply, contact us.
*5 Effective length is for static elimination range when installation distance is 100 mm.

Back to top

Model

SJ-Q156

SJ-Q180

SJ-Q204

SJ-Q228

SJ-Q252

SJ-Q300

Image

Data Sheet (PDF)

Download

Download

Download

Download

Download

Download

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/
applied voltage

Pulse AC method/±8000 Vmax

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±3 V *1

Clean rating

ISO14644-1 Class 3 *2

Operating distance

10 mm or more

Control input

Static elimination stop input

NPN open collector or non-voltage contact signal

Control output

Ion level alarm

NPN open collector
Maximum 100 mA (40 VDC or less)

Condition alarm

Alarm output

Communication functions

Remote control

Average power consumption

Normal operation: 8.4 W,
LPC mode: 4.1 W
*3

Major features

Condition alarm, ion level alarm, alarm output

Air connection port

Rc1/8

Air supply pressure

0.1 to 0.5 MPa (recommended air pressure: 0.2 MPa)*4

Effective length

1640 mm *5

1880 mm *5

2120 mm *5

2360 mm *5

2600 mm *5

3080 mm *5

Total length

1520 mm

1760 mm

2000 mm

2240 mm

2480 mm

2960 mm

No. of electrodes

25

29

33

37

41

49

Rating

Power voltage

24 to 36 VDC±10%

Current consumption

Normal operation: 700 mA or less,
LPC mode: 170 mA (typical)
*3

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C

Relative humidity

85% RH or less (no condensation)

Material

Electrode probe

Tungsten

Body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1800 g

2010 g

2230 g

2440 g

2660 g

3090 g

*1 Measured under the following conditions.
Installation distance: 300 mm, Air supply pressure: 0.2 MPa, Frequency: Highest device driving frequency, Operating ambient temperature: 0 to +40°C, Operating ambient humidity: 35 to 65% RH, Measurement position: Bar centre
*2 Contact us for detailed conditions.
*3 24 VDC
*4 If you wish to use the air purge function with intermittent air supply, contact us.
*5 Effective length is for static elimination range when installation distance is 100 mm.

Back to top